Features for Patient Monitor:
1.Ergonomic design, portable, convenient for use
2.12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
3.Unique digital SPO2 technology can work accurate during motion and low perfusion
4.Anti AC & high-frequency electrosurgical & defibrillator’s interference
5.Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
6.Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
7.ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
8.Audible & visual alarm available, adjustable
9.Patient information management function
10.Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
11.Optional software upgrading based on USB
12.Wired/wireless networking with central monitoring system, up to 64 beds in one group
13.Built-in 3 trace thermal recorder for printing real-time and historical data
14.Multi-language i.e. English, Spanish, Turkish.
15.Super long life rechargeable Lithium battery upto 4 hours of working time
16.Suitable for adult, pediatrics and neonate patients
Standard Configuration:
ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
Specification for Patient Monitor:
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
ST section
Scope: ±0.8mV
Precision : < ±0.05mV
SpO2
Detection scope: 0%-100%
Accuracy ±1% 90%-100%
±2% 70%-89%
NIBP
Theory Electric oscillator
Cuff gassing time less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 min -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg)
Detection accuracy Static pressure: ±3mmHg
Pulse rate: ±2%
Resp
Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute – 100 minutes/minute
Precision of chest impedance method time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute
Temp
Single/double path
Type: Vascular/surface temperature
Scope: 20℃~50℃
Accuracy: ±0.2℃
Warranty: One Year! Service: Whole Life!